APC MGE Galaxy 3500 15kVA 400V with 4 Battery Modules, Start-up 5X8

MGE GALAXY 3500 15KVA 400V W/ 4 BATTERY MODUL. START-UP 5X8
Australian stock.Standard manufacturer's warranty for Australia applies. Please refer to the manufacturer's website for warranty details.
  • Our SKU #
    Manufacturer's #
  • 28849
    -
  • Manufacturer's #
  • G35T15KH4B4S

$18,102.75
Not in stock
By Order
Calculate Shipping Cost

APC MGE Galaxy 3500,12 kW /15 kVA,Input 400V 3PH /Output 400V 3PH, Interface Port DB-9 RS-232, G35T, Extended runtime model

Specifications

Output
Output Power Capacity 12 kW/ 15 kVA
Max Configurable Power 12 kW/ 15 kVA
Nominal Output Voltage 400V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 95.8%
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal
Other Output Voltages 380, 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections (1) Hard Wire 4-wire (3PH + G) (1) Hard Wire 5-wire (3PH + N + G) (1) Screw Terminals
Output Voltage Tolerance +/- 5% static and 100% load step
Output Voltage THD
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 95.3%
Required Output Current Protection 25A
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 304 - 477V
Input voltage adjustable range for mains operation 340 - 460 (400V)V
Other Input Voltages 380, 415
Maximum Input Current 20A
Input Breaker Capacity 25  A
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules 4
Typical recharge time 5 hour(s)
Nominal Battery Voltage +/-192 V (split battery referenced to neutral)
End of Discharge Battery Voltage +/-154 V
Efficiency in Battery Operation 95.10%
End of Discharge Maximum Battery Current 109
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Extended Run Options MGE Galaxy 3500 15kVA 400V with 4 Battery Modules, Start-up 5X8

Includes:

  • Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Power modules ship installed, Smart UPS signalling RS-232 cable, Start-Up Service, User Manual