Eaton 5130 Rack/Tower Line interactive UPS

5130 SERIES RACK/TOWER 2U, LINE INTERACTIVE UPS
Australian stock.Standard manufacturer's warranty for Australia applies. Please refer to the manufacturer's website for warranty details.
Calculate Shipping Cost

The Eaton 5130 Rack/Tower UPS provides line-interactive backup power and scalable runtimes for servers, storage systems, VoIP gear and network equipment. With a two-in-one rack/tower form factor, the 5130 UPS packs up to three kVA of power into only 2U of rack space.

The 5130 UPS provides additional battery runtime with 2U extended battery modules. To enhance compatibility with modern IT loads, the 5130 UPS is designed with a 0.9 power factor.

  • Power Rating: 1250-3000 VA
  • Voltage: 230 Vac
  • Frequency: 50/60 Hz (auto- sensing)
  • Configuration: Rack/Tower
  • Product Series: Powerware

Product Variants

  • Our SKU #
    Manufacturer's #
  • 06904
    -
  • Manufacturer's #
  • PW5130N3000-EBM2U

3000 R/T EBM 2U

Eaton 5130 Rack/Tower Line interactive UPS (3000 R/T EBM 2U)

2U Extended Battery Module (EBM) giving additional runtime for Eaton 5130 2200, 2500 and 3000 UPSs - up to 4 EBMs can be attached to each UPS.

$991.88
Not in stock
By Order

  • Our SKU #
    Manufacturer's #
  • 06905
    -
  • Manufacturer's #
  • PW5130N1750-EBM2U

1750 R/T EBM 2U

Eaton 5130 Rack/Tower Line interactive UPS (1750 R/T EBM 2U)

2U Extended Battery Module (EBM) giving additional runtime for Eaton 5130 1000, 1250, 1500 and 1750 UPSs - up to 4 EBMs can be attached to each UPS.

$809.79
Not in stock
By Order
LEDs 13 status-indicating LEDs
Topology Line interactive
Diagnostics Full system self-test at power up
Transfer Time 1–4 ms typical
ROO/RPO Rear deck emergency stop connector (for remote on/off and power off)
Rail Kit/Tower Stand Included with all units
Electrical Input
Nominal Voltage 230 Vac
Voltage Range 160–294V
(* The high and low thresholds can be user adjusted using the downloadable UPS Configuration tool)
Frequency 50/60 Hz
Frequency Range 47–70 Hz for 50 Hz operation
56.5–70 Hz for 60 Hz operation
Power Draw of UPS (full load) 1250: 5.4A @230V
1750: 7.6A @230V
2500: 10.9A @230V
3000: 13.0A @230V
Electrical Output
Power Factor 0.9
On Utility Voltage Regulation 184–265 Vac
On Battery Voltage Regulation -10%, +6% of nominal
Efficiency Normal or line mode: >94%
Frequency Regulation 0.1 Hz
Over Current Protection Electronic current limit
Load Crest Factor 3:1
Load Segments Two individually controlled output receptacles